If you buy our CFI-I practice engine, you can get rewords more than you can imagine. On the one hand, you can elevate your working skills after finishing learning our CFI-I study materials. On the other hand, you will have the chance to pass the exam and obtain the CFI-Icertificate, which can aid your daily work and get promotion. All in all, learning never stops! It is up to your decision now. Do not regret for you past and look to the future.

NFPA CFI-I Exam Syllabus Topics:

TopicDetails
Topic 1
  • Storage, Handling, & Use of Hazardous Substances and Materials: This module measures the skills of Fire Inspectors and includes recognizing hazardous conditions in equipment, processes, and operations.
Topic 2
  • Occupancy Types: This section tests the abilities of exam-takers to assess fire and life safety systems for different occupancy types, including assembly, educational, and healthcare facilities.
Topic 3
  • Administration: This section of the exam measures the skills of Fire Inspectors and covers the preparation of inspection reports, identifying the need for permits, and recognizing when plan reviews are required. It also involves investigating complaints, identifying applicable codes, and participating in legal proceedings. One key skill measured is communicating findings clearly in written reports.
Topic 4
  • Fire Protection Systems & Equipment: This section evaluates the skills of Fire Safety Technicians and focuses on determining the operational readiness of fire suppression systems, alarm systems, and portable fire extinguishers.

>> Pdf CFI-I Files <<

Official NFPA CFI-I Practice Test, CFI-I Valid Test Online

The aim that we try our best to develop the CFI-I exam software is to save you money and time, and offer the effective help for you to pass the exam during your preparation for CFI-I exam. Our software has help more CFI-I exam candidates get the exam certification, but no matter how high our pass rate is, we still guarantee that if you fail the CFI-I Exam, we will full refund the money you purchased the CFI-I exam software, which makes you be more rest assured to purchase our product.

NFPA Certified Fire Inspector I (CFI-1) Sample Questions (Q78-Q83):

NEW QUESTION # 78
To transfer Class I flammable liquids by pressurizing the tank, which of the following conditions must be met?
I . Inert gas is used to pressurize the tank.
II . Air is used to pressurize the tank.
III . A pressure relief device shall be provided.
IV . An interlock shall be installed on the container.

  • A. II and IV
  • B. II and III
  • C. I and III
  • D. I and IV

Answer: C

Explanation:
Transferring Class I flammable liquids involves strict safety conditions to prevent fire or explosion risks. According to NFPA 30, Flammable and Combustible Liquids Code:
Inert gas (I): Pressurizing the tank with inert gas (e.g., nitrogen) is required to prevent the creation of a flammable atmosphere. Air (II) is not acceptable because it introduces oxygen, which can result in combustion.
Pressure relief device (III): A pressure relief device is mandatory to prevent over-pressurization, which could cause a tank failure or explosion.
Interlock (IV): While useful for operational safety, it is not specifically required for pressurizing tanks.
Reference:
NFPA 30, Chapter 18: Requirements for transferring flammable liquids under pressure.


NEW QUESTION # 79
What is the maximum permitted height for stored Class 2 oxidizers in a nonsprinklered retail sales area that is open to the public?

  • A. 5 ft (1.5 m)
  • B. 12 ft (3.7 m)
  • C. 3 ft (1.0 m)
  • D. 6 ft (1.8 m)

Answer: A

Explanation:
Comprehensive and Detailed Step-by-Step Explanation:
Storage of Class 2 Oxidizers:
Per NFPA 430 (Code for the Storage of Liquid and Solid Oxidizers), Section 6.3.4, in nonsprinklered retail sales areas open to the public, Class 2 oxidizers must not be stored at heights exceeding 5 feet (1.5 meters).
Why 5 Feet is the Limit:
Limiting the height reduces the risk of spills, accidental damage, and fire spread in a retail environment.
Other Options Explained:
Option A (3 ft): Too restrictive; NFPA allows up to 5 ft.
Option C (6 ft) and Option D (12 ft): Exceed the maximum permitted height for nonsprinklered areas.
Summary:
The maximum height for stored Class 2 oxidizers in a nonsprinklered retail area open to the public is 5 feet (1.5 meters).


NEW QUESTION # 80
How often should manual fire alarm boxes be visually inspected?

  • A. Annually
  • B. Monthly
  • C. Semiannually
  • D. Weekly

Answer: B

Explanation:
Visual inspections for fire alarm system components are outlined in NFPA 72, National Fire Alarm and Signaling Code, Table 14.3.1.
Monthly (B): Manual fire alarm boxes must be visually inspected monthly to ensure they are free from obstructions and visible to occupants.
Weekly (A): Weekly inspections are not required for manual pull stations.
Semiannually (C) and Annually (D): These intervals apply to other maintenance tasks, such as functional testing, not visual inspections.
Reference:
NFPA 72, Table 14.3.1: Inspection intervals for manual fire alarm boxes.


NEW QUESTION # 81
How often are fire drills required for each shift of an acute care hospital?

  • A. Annually
  • B. Semiannually
  • C. Monthly
  • D. Quarterly

Answer: D

Explanation:
Comprehensive and Detailed Step-by-Step Explanation:
Fire Drills in Health Care Facilities:
According to NFPA 101 (Life Safety Code), Section 19.7.1.6, fire drills in acute care hospitals must be conducted quarterly on each shift.
This ensures staff on all shifts are prepared to respond appropriately in an emergency.
Why Quarterly is Required:
Regular drills help reinforce response protocols and ensure compliance with fire safety standards.
Other Options Explained:
Option A (Monthly): Exceeds the minimum requirement of quarterly drills.
Option C (Semiannually) and Option D (Annually): Insufficient to meet the requirements for high-risk environments like hospitals.
Summary:
Fire drills in acute care hospitals must be conducted quarterly for each shift to ensure readiness and compliance.


NEW QUESTION # 82
What is the color of a heat-sensing fire detector with a temperature classification of extra high?

  • A. White
  • B. Red
  • C. Blue
  • D. Green

Answer: B

Explanation:
Comprehensive and Detailed Step-by-Step Explanation:
Heat Detector Color Codes:
According to NFPA 72 (National Fire Alarm and Signaling Code), heat-sensing fire detectors are color-coded based on their temperature classification:
White: Ordinary (135°F to 155°F).
Green: Intermediate (175°F to 225°F).
Blue: High (250°F to 300°F).
Red: Extra high (325°F to 375°F).
Why Red is the Correct answer:
Heat detectors classified as extra high operate at temperatures between 325°F and 375°F and are marked with a red color code.
Other Options Explained:
Option A (White): Ordinary temperature range.
Option B (Green): Intermediate temperature range.
Option C (Blue): High temperature range.
Summary:
The color of a heat-sensing fire detector with an extra high temperature classification is red.


NEW QUESTION # 83
......

With our NFPA CFI-I study material, you'll be able to make the most of your time to ace the test. Despite what other courses might tell you, let us prove that studying with us is the best choice for passing your NFPA CFI-I Certification Exam! If you want to increase your chances of success and pass your CFI-I exam, start learning with us right away!